#
#	@(#)gettydefs	1.5 91/02/01
#
# This file contains information used by getty(M) to set up the speed and
# terminal settings for a line.
#

#
# The following entries { 0, 1, ..., 6, 7 } are for MODEM ports.
#

#
# Modem at fixed baud rate of 9600.
#

0 # B9600 HUPCL # B9600 HUPCL CS8 SANE TAB3 ECHOE IXOFF IXANY #\r\n@ login: # 0

#
# The sequence for {1,2,3} is 2400 -> 1200 -> 300 -> 2400 etc.
#

1 # B300  HUPCL CS8 OPOST CR1 NL1 #
	B300  HUPCL CS8 SANE TAB3 IXANY #\r\n@ login: # 3

2 # B1200 HUPCL CS8 OPOST CR1 NL1 ECHOE #
	B1200 HUPCL CS8 SANE TAB3 ECHOE IXANY #\r\n@ login: # 1

3 # B2400 HUPCL CS8 OPOST CR1 NL1 ECHOE #
	B2400 HUPCL CS8 SANE TAB3 ECHOE IXANY #\r\n@ login: # 2

#
# The sequence for {4,5,6,7} is 19200 -> 9600 -> 4800 -> 2400 -> 19200 etc.
#

4 # B2400  HUPCL CS8 #
	B2400  HUPCL CS8 SANE TAB3 ECHOE IXOFF IXANY #\r\n@ login: # 7

5 # B4800  HUPCL CS8 #
	B4800  HUPCL CS8 SANE TAB3 ECHOE IXOFF IXANY #\r\n@ login: # 4

6 # B9600  HUPCL CS8 #
	B9600  HUPCL CS8 SANE TAB3 ECHOE IXOFF IXANY #\r\n@ login: # 5

7 # B19200 HUPCL CS8 #
	B19200 HUPCL CS8 SANE TAB3 ECHOE IXOFF IXANY #\r\n@ login: # 6

#
# The following entries { a, b, ..., n, o } are for
# direct connect ports at fixed baud rates.
#
# a: 50 baud 
#	...
# m: 9600 baud
# n: 19200 baud
# o: 38400 baud
#

a # B50   CLOCAL CS8 #
	B50   CLOCAL CS8 SANE DTRFLOW IXANY #\r\n@ login: # a

b # B75   CLOCAL CS8 #
	B75   CLOCAL CS8 SANE DTRFLOW IXANY #\r\n@ login: # b

c # B110  CLOCAL CS8 #
	B110  CLOCAL CS8 SANE DTRFLOW IXANY #\r\n@ login: # c

d # B134  CLOCAL CS8 CSTOPB #
	B134  CLOCAL CS8 CSTOPB SANE DTRFLOW IXANY #\r\n@ login: # d

e # B150  CLOCAL CS8 #
	B150  CLOCAL CS8 SANE DTRFLOW IXANY #\r\n@ login: # e

f # B200  CLOCAL CS8 #
	B200  CLOCAL CS8 SANE DTRFLOW IXANY #\r\n@ login: # f

g # B300  CLOCAL CS8 #
	B300  CLOCAL CS8 SANE DTRFLOW IXANY #\r\n@ login: # g

h # B600  CLOCAL CS8 #
	B600  CLOCAL CS8 SANE DTRFLOW IXANY #\r\n@ login: # h

i # B1200 CLOCAL CS8 #
	B1200 CLOCAL CS8 SANE ECHOE DTRFLOW IXANY #\r\n@ login: # i

j # B1800 CLOCAL CS8 #
	B1800 CLOCAL CS8 SANE ECHOE DTRFLOW IXANY #\r\n@ login: # j

k # B2400 CLOCAL CS8 #
	B2400 CLOCAL CS8 SANE ECHOE DTRFLOW IXANY #\r\n@ login: # k

l # B4800 CLOCAL CS8 #
	B4800 CLOCAL CS8 SANE ECHOE DTRFLOW IXANY #\r\n@ login: # l

m # B9600 CLOCAL CS8 #
	B9600 CLOCAL CS8 SANE ECHOE DTRFLOW IXANY #\r\n@ login: # m

n # B19200 CLOCAL CS8 #
	B19200 CLOCAL CS8 SANE ECHOE DTRFLOW IXANY #\r\n@ login: # n

o # B38400 CLOCAL CS8 #
	B38400 CLOCAL CS8 SANE ECHOE DTRFLOW IXANY #\r\n@ login: # o

#
# End of normal direct-connect entries.
#

#
# The following entries are for com1/com2 when used as system console.
#

console# B9600 CS8 PARENB OPOST ONLCR ECHO #
	B9600 CS8 PARENB SANE ECHOE ISTRIP IXANY #Console Login: #console1

console1# B1200 CS8 PARENB OPOST ONLCR ECHO #
	B1200 CS8 PARENB SANE ECHOE ISTRIP IXANY #Console Login: #console2

console2# B300 CS8 PARENB OPOST ONLCR ECHO #
	B300 CS8 PARENB SANE ECHOE ISTRIP IXANY #Console Login: #console3

console3# B2400 CS8 PARENB OPOST ONLCR ECHO #
	B2400 CS8 PARENB SANE ECHOE ISTRIP IXANY #Console Login: #console4

console4# B4800 CS8 PARENB OPOST ONLCR ECHO #
	B4800 CS8 PARENB SANE ECHOE ISTRIP IXANY #Console Login: #console5

console5# B19200 CS8 PARENB OPOST ONLCR ECHO #
	B19200 CS8 PARENB SANE ECHOE ISTRIP IXANY #Console Login: #console

